Velocity measurement, material transport

SpeedFlow 2.0-Pipe

Velocity measurement in full cross-section version. Continuous velocity measurement in tube version for careful material transport. Measures in full cross-section.

The system operates with no contact in a process in which the material movement is detected by using the Doppler effect.

The FlowJam is a process-secure device, since the microwave technology used can penetrate material coating on the sensor and reliably detect the material movement behind it. If container walls, housings or pipelines are not metal, it is possible to measure from the outside.

  • Continuous speed measurement of solids (powder, granules, dust ) in metal pipes
  • Measurement directly in the conveying stream / entrained flow
  • Measurement is completely independent of material
  • Sensor is made accordingly to the existing pipe diameter
  • Measurement without product contact
  • Plastic industry
  • Tobacco
  • Food

Application examples:

Technical Specifications
Material to measure Dust, powders or granulates
Working principle Correlation, integrated, ful cross-section
Process pressure Max. 100 mbar
Process temperature Max. +45°C
Mounting JACOBS flange
Type of Conveying Pneumatic leanphase
Velocity range 1…35m/s
Pipe diameter Max. 350mm
ATEX rating None
Output 4…20mA, Modbus, Profibus
  • Materials: Granules, Powder and dust
  • No calibration (Plug & Play)
  • Without build-in components into the flow
  • Range of application: starts with material speed as low as 0.75 m/s
Sensor Technical Data
Innerdiameter DN: 80, 100, 150, 200, 250, 350
(other sizes on request)
Material inner pipe PMMA
Mechanical connection JACOBS flange
Protection category IP 54
Max. pressure 100 mbar
Velocity range 1…35 m/s/td>
Temperature inside the pipe 0…+50 °C
Temperatur outside the pipe 0…+45 °C
Power supply 24 V DC
Weight Depend on diameter
Measuring accuracy ± 1 %
(in the calibrated measuring range)
Transmitter Technical Data
Transmitter (DIN Rail) Transmitter (field housing)
Power supply 24 V DC ±10 % 110 / 230 V AC 50 Hz
(optional 24 V DC)
Power consumption 20 W / 24 VA
Protection type IP 40 to EN 60 529 IP 65 to EN 60 529/10.91
Ambient operating temperature -10 … +45 °C
Dimensions (W x H x D) 23 x 90 x 118 mm 258 x 237 x 174 mm
Weight Approx. 172 g Approx. 2.5 kg
Connection terminals cable
cross-section
0.2-2.5 mm2 [AWG 24-14]
Current output 1 x 4 … 20 mA (0 … 20 mA),
load < 500 Ω
3 x 4 … 20 mA (0 … 20 mA),
load < 500 Ω
Interface RS 485 (ModBus RTU) / USB
Pulse output Open collector – max. 30 V, 20 mA
Relay contact Max. rated load:
250 V AC
Max. peak current:
6 A
Max. rated load 230 V AC:
250 VA
Max. breaking capacity DC1:
3/110/220 V: 3/0.35/0.2 A
Min. switching load:
500 mW (10 V / 5 mA)
Data backup Flash memory

Related products

  • AirSafe 2

    Continuous dust monitoring in ambient air: control system areas, silo areas, boiler houses, work stations

    More
    0.00
  • SpeedFlow 2.0

    Continous speed measurement for solids usable in free fall and pneumatics

    More
    0.00
  • FlowJam Plus

    Material flow monitoring with Flow/No Flow information plus additional "Detection of blockage" or "Material flow interruption" function (Jam/NoJam)

    More
    0.00
  • ProGap 2.0

    Microwawe barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fill level and limit detection

    More
    0.00
QUOTE CONTACT REQUEST

Compare up to 5 products Show

Previous Next
Close
Test Caption
Test Description goes like this

SOLUTIONS

SERVICES & SUPPORT

NEWS & EVENTS

ABOUT US

CONTACT

This site uses cookies. By the further use you hereby agree. For detailed information, please refer to the Cookies. Ok