NDIR Multi-Gas Analyzer

MIR 9000e

Eco-designed, ultra-compact, smart & connected instrument, the MIR 9000e is your next tool to measure combustion exhaust gas from boiler, or gas from different industrial furnaces and process applications.

Eco-designed, ultra-compact, smart & connected instrument, the MIR 9000e offer superior metrological performances for the simultaneous multi-gas measurement of: NOx, SO2, CO, O2, residual H2O, and optionnally CO2, CH4 and N2O (greenhouse gases)

NEW generation
  • Superior metrological performances for the simultaneous multi-gas measurement of: NOx, SO2, CO, O2, residual H2O, and optionnally CO2, CH4 and N2O (greenhouse gases)
  • Environmental-friendly and cost-saving analyzer, with ultra low power consumption
  • No compressed air required (if using a gas cooler)
  • Insensitive to T° variations in the range +5° to +40°C (no air conditioning required)
  • Compatible with any type of drying technology (gas cooler, permeation, dilution…)
  • Breakthrough mechanical design for weight and power saving as well as thermal insulation & reliability
  • Proactive, user-friendly remote communication
  • Smart analyzer including AMS control functionnalities: integrated sampling control, automatic zero and span gas injection, external pump control, system alarms display…
  • Highly accurate, excellent stability, economical, easy and reduced maintenance
  • Industrial Boilers and Furnaces
  • Power Generation & Combustion
  • Gas turbines
  • Chemical & Petrochemical Plants
  • Process gas monitoring…
Measuring Ranges
NOx as NO2
(after NOx converter)
0 – 100 / 0 – 1500 mg/m3
SO2 0 – 75 / 0 – 1500 mg/m3
CO 0 – 75 / 0 – 3000 mg/m3
O2 0 – 25%
Residual H2O 0 – 2%
Optional parameters:
CO2 0 – 20 / 0 – 30 %
CH4 0 – 100 / 0 – 200 mg/m3
N2O 0 – 100 / 0 – 200 mg/m3
Technical Specifications
QAL1 to EN 15267-3 certified ongoing
US EPA compliance YES
Sampling technology Cold/Dry Extraction
Sample transfert non heated polytube
back flush function YES
span injection YES on analyser or at sample point
Built-In O2 option YES
Serial link communication RS232 / RS422
Other Communication Ethernet
Analogue OUTPUTS Optional
Analogue INPUTS Optional
Dimensions (mm) 19’’ rack, 3U; 483x330x133 mm (DxWxH)

Complete systems would comprise of:

  • Sampling and conditioning system
  • Sampling lines
  • NOx converter
  • Data acquisition & management system

Related products

QUOTE CONTACT

Compare up to 5 products Show