ElectroDynamic® Filter Dust/Leak Monitor

PCME LEAK ALERT 65-02

Controller based filter dust leak monitor (0-100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones etc. where performance approvals are not required

  • Reliable monitoring of leaking and broken bags in dust collectors
  • Sensor configured remotly via controller
  • Manual sensor Drift Checks (zero and span)
  • Probe Check (Insulator Short-Circuit Check) option for improved data integrity
  • Digital display and optional graphical display to view live data and monitor bag cleaning cycle
  • Reduces filter maintenance intervals, process down-time and filter costs
  • Stacks after bag filters, cartridge filters, cyclones
  • Variable velocities within range 4-30m/s (typical bagfilter velocity ranges), constant velocity required outside this range
    Typical Applications:

  • Incineraton
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg Detergent / Ti02)
  • Food (eg Milk Powder / Tobbacco)
  • Power (eg Boilers/Biomass)
Technical Specifications
Measured parameters Dust
Technology ElectroDynamic® Advanced Probe Electrification
Measurement/Monitoring capability 0-500 mg/m³*
Stack/Duct diameter suitability up to 6m
Flue gas temperature up to 400°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter /
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) /
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
Fully insulated PTFE coated
QA checks YES
*Application dependant
Technical data
Monitoring capability 0-500 mg/m3
Sensor Variants 316 Stainless Steel (standard) / Fully insulated PTFE coated (option)
Stack Temperature Ranges 0-250°C standard, up to 400°C option
Functionality and QA Checks Drift checks (zero and span), Probe short circuit check option
Output Optional RS232, RS485 (Modbus) 2 x Digital Alarm and 4/20mA
Air Purge option
  • US EPA MACT Compliant BLD
  • Ex Zone 2, 20

Related products

  • PCME LEAK ALERT 75

    Stand alone TÜV approved filter dust leak monitor suited to the monitoring of filter emissions (0-100%) after bag houses, cartridge filters, cyclones etc

    More
    10.00
  • AirSafe

    Continuous dust monitoring in ambient air: control system areas, silo areas, boiler houses, work stations

    More
    10.00
  • MIR 9000

    Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2.

    More
    10.00
  • PicoFlow

    Perfectly adapted for control and regulation of reagent in flue gas treatment and transport lines with very low material concentration

    More
    10.00

Compare up to 4 products Show

Le nouveau site d’ENVEA est actuellement en cours de développement, fermez cette fenêtre pour poursuivre votre navigation. Vous pouvez aussi retrouver l’intégralité des rubriques en cliquant sur le bouton ci-dessous.

The new ENVEA website is currently under development, close this window to proceed your navigation. You can also find all the sections by clicking on the button below.
ENVEA
close-link
This site uses cookies. By the further use you hereby agree. For detailed information, please refer to the Cookies. Ok