Mercury analyzer for water and aqueous solutions in Process applications

PA-2 / PA2-Gold

The mercury analyzer PA-2 is used for continuous monitoring of mercury concentrations in industrial processes.

The PA-2 was specially designed for process analysis and operation under harsh industrial condition. The system comes with either the VM-3000 or the UT-3000 photometer to meet different requirements regarding accuracy and sensitivity of measurements.

Add to Compare
  • Fully automatic system
  • Easy menu-driven operation
  • Proven and reliable detection method: AAS
  • Measuring ranges from 10 ppt to 100 ppm
  • High flexibility of sample pretreatment
  • Suited for complex sample compositions
  • Low reagent consumption
  • Corrosion-protected construction
  • Automatic self diagnosis system for reliable operation
  • Quality control in chlorine-alkali plants
  • Monitoring of scrubber water of waste incinerators and power plants
  • Control of industrial sewage
  • Control of purification plants
  • Quality control of sulphuric acid
  • Quality control of drinking water
Technical Specifications
Measuring principle Amalgamation on MI GoldTrap (PA-2 Gold only), cold vapor atomic absorption (CVAAS) at 253.7 nm
UV-Source Electrodeless low pressure mercury lamp (EDL)
Stabilization method Reference beam method
Optical cell Fused silica (Suprasil), lapprox. 230mm, heated approx. 55°
Measuring ranges PA-2 0.1 … 1 µg/l to 0…10 mg/l
Measuring ranges PA-2 Gold 0.01 … 1 μg/l to 0.1 … 10 μg/l
Sensitivity > 0.01 µg/l
Response time approx. 1 minute
Sample flow approx. 20 l/h
Carrier gas compressed air, filtered, approx. 30l/h, 1bar
Reduction reagent Tin-II-chloride or Sodiumhydroborate
Reagent consumption approx. 3l/week for each reagent
Sample digestion HCl or H2SO4, KMnO4 or H2O2 or Fenton’s Reagent or NaClO3; depending on sample composition
Technical Data
Signal outputs analogue: 4 – 20 mA (500 Ω max.);
serial: RS232 / USB/td>
Status output Calibration; Autozero; Service; Malfunction; according to NAMUR 64 recommendations
Housing Fibreglass-reinforced polyester, for use in highly corrosive environment – Reagent storage cabinet made of chemically resistent plastic material/td>
Protection class IP 66 (EN 60529/ NEMA 3; 3R; 4; 4X; 12; 13)
Operating temperature 0 to 40°C
Sample temperature 65°C
Power supply 230 VAC / 50 Hz (110 VAC / 60 Hz option)
El. Power consumption 750 VA max. (PA-2 Gold, heating peak)
Dimensions (W x H x D) 62 x 78 x 33 cm
Weight approx. 50 kg
  • Our products are manufactured according to the ISO 9001 quality regulations.
  • CE approved

ENVEA’s Process Catalogue

Related products

Produits apparentés

Verwandte Produkte

Prodotti correlati

Productos relacionados

相关产品

Produtos relacionados

Сопутствующие товары

QUOTE DEVIS ANGEBOT OFFERTA COTIZACIÓN COTAÇÃO ЗАПРОС ЦЕНЫ CONTACT CONTACT KONTAKT CONTATTI CONTACTO CONTATO КОНТАКТЫ