ElectroDynamic® Filter Dust/Leak Monitor

PCME LEAK ALERT 75

Stand alone TÜV approved filter dust leak monitor suited to the monitoring of filter emissions (0-100%) after bag houses, cartridge filters, cyclones etc

  • Reliable monitoring of leaking and broken bags in dust collectors
  • External Display
  • In-built sensor Drift Checks (zero and span)
  • Probe Check (Insulator Short-Circuit Check) option for improved data integrity
  • Reduces filter maintenance intervals, process down-time and filter costs
  • Stacks after bag filters, cartridge filters, cyclones
  • Variable velocities within range 4-30m/s (typical bagfilter velocity ranges), constant velocity required outside this range
    Typical Applications:

  • Incineraton
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg Detergent / Ti02)
  • Food (eg Milk Powder / Tobbacco)
  • Power (eg Boilers/Biomass)
Technical Specifications
Measured parameters Dust
Technology ElectroDynamic® Advanced Probe Electrification
Measurement/Monitoring capability 0-500 mg/m³*
Stack/Duct diameter suitability up to 6m
Flue gas temperature up to 400°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter /
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) /
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
Fully insulated PTFE coated
QA checks YES
*Application dependant
Technical Data
Measurement capability 0-500 mg/m3
Sensor Variants 316 Stainless Steel (standard) / Fully insulated PTFE coated (option)
Stack Temperature Ranges 0-250°C standard, up to 400°C option
Functionality and QA Checks Drift check (zero and span), Probe short circuit check option
Outputs Optional RS232, RS485 (Modbus)
2 x Digital Alarm and 4/20mA
Air Purge Option
  • TÜV Approved (EN 15859) Filter Dust Monitor
  • US EPA MACT Compliant BLD
  • Ex Zone 20

Related products

  • PCME QAL 991

    QAL1 approved particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge Filters

    More
    0.00
  • PCME LEAK ALERT 73

    Stand alone filter dust leak monitor (0-100%) for filter emissions monitoring after baghouses, cartridge filters, cyclones etc. where performance approvals are not required

    More
    0.00
  • MIR 9000

    Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2.

    More
    0.00
  • AirSafe 2

    Continuous dust monitoring in ambient air: control system areas, silo areas, boiler houses, work stations

    More
    0.00
QUOTE CONTACT REQUEST

Compare up to 5 products Show