In-situ Cross-Duct TDLAS Analyzer

LAS 300 XD

In-situ & non-invasive measurement of NH3 & H2O, HCl & H2O, HF, low or high concentrations of CO and O2

The Tunable Diode Laser Spectroscopy (TDLS) is the perfect technology to use when you are looking for a selective measurement and a fast response time on some gas components as NH3, HCL, HF or even O2 when conditions are too rough for standard O2 Zirconia In-Situ analysers.

Tunable Diode Laser Absorption Spectrometry is the future of raw gas measurement
  • Available versions:
    LAS 300XD NH3 for ammonia (NH3) and water (H2O) monitoring
    LAS 300XD CO for low and high concentration carbon monoxide (CO) monitoring
    LAS 300XD HCl for hydrochloric acid (HCl) and water (H2O) monitoring
    LAS 300XD HF for hydrofluoric acid (HF) monitoring
    LAS 300XD O2 for oxygen (O2) monitoring
  • Suitable for harsh environment; sensor unaffected by contaminants (no corrosion)
  • Absence of extractive conditioning: eliminates errors related to sample handling
  • Absolute measurements: no drift, no calibration, linear response
  • Very low maintenance, low cost of ownership
  • In-situ & non-invasive measurement (optical technique)
  • Interference free gas measurements
  • Large dynamic range
  • Compact system
  • Real-time – 1s response
  • High sensitivity – ppb, ppm and % concentrations
  • No sample lines required, eliminating errors due to gas sampling
  • Scrubber technology
  • Combustion control
  • Chemical industry
  • Fertilizer plants
  • Waste incinerators
  • Cement industry
  • Glass industry
  • Pulp and paper
  • Biomass boilers
  • Petrochemical industry
Measurable parameters
Pollutant Range
(ppm)
Product
code
HCI 0-10 / 3000
HF 0 / 100
CO Low: 0-500 / High: 0-1-100%
NH3 0-15 / 500
H2O(%) 0-5 / 50
O2(%) 0-10 / 100
Lowest / Highest available ranges (may vary with your site conditions to be indicated on the Site Survey Form)

Technical Specifications
QAL1 to EN 15267-3 certified N/A
US EPA compliance N/A
Sampling technology In-Situ
Sample transfert N/A
Back flush function YES (Purge)
Span injection Optional: In Line Cell on receiver
Built-In O2 option NO
Serial link communication Modbus RTU
Other Communication NO
Analogue OUTPUTS YES (x 2)
Analogue INPUTS YES (x 2)
Dimensions (mm) 2 x Compact enclosures: 170 x 243 x 209 mm (L x W x H) each
    Complete system would normally comprise of:

  • Transmitter and receiver units
  • 2 alignment flanges (DN40 / PN10)
  • 2x Analog inputs/outputs
  • 2x Relay contacts
  • Modbus RTU RS485
  • LaserTool® software

Related products

QUOTE CONTACT

Compare up to 5 products Show

Previous Next
Close
Test Caption
Test Description goes like this

SOLUTIONS

SERVICES & SUPPORT

NEWS & EVENTS

ABOUT US

CONTACT

This site uses cookies. By the further use you hereby agree. For detailed information, please refer to the Cookies. Ok