QAL1 Forward Scatter Particulate CEM

PCME QAL 181

QAL1 Approved ProScatter™ particulate CEM providing high quality emission measurement of low dust concentrations from dry industrial processes

  • Robust design with no critical moving parts
  • Available for use in high-temperature stack conditions and Ex hazardous zones
  • Easy to fit multi-patterned flange
  • Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
  • Enhanced measurement due to reduced cross sensitivity to particle type and size
  • ProScatter® technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
  • Easily audited with manual filters
  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases
    Typical Applications:

  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg TiO2 / Refinery)
  • Power Generation Plant (eg Coal/Biomass)
Technical Specifications
Measured parameters Dust
Technology ProScatterTM Forward Scatter
Measurement/Monitoring capability 0-1000 mg/m³*
Stack/Duct diameter suitability up to 8m
Flue gas temperature up to 500°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
Hastelloy® corrosion resistant
QA checks YES
*Application dependant
Technical data
Measurement capability 0 – 1000 mg/m3
Certification Range 0 – 15 mg/m3
0 – 100 mg/m3
Resolution 0.01 mg/m3
Sensor Variants Stainless Steel (standard). Corrosion resistant Hastelloy (option)
Stack Temperature Ranges 0-250°C. Up to 500°C option
Functionality and QA Checks Automatic zero and upscale checks QA data logging
Data Output RS485 (Modbus) output to Controller
Air Purge requires continuous air purge
Enclosure Protection Rating IP66
  • MCERTs and TÜV (UBA) certified to EN15267-3
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181
  • GOST / EAC Approved
  • Ex Zone 2

Related products

  • PCME STACKFLOW 400

    Approved flue gas velocity CEM for stack velocity, volumetric flow and pollutant mass release calculations when linked to Gas and Dust CEMS

    More
    0.00
QUOTE CONTACT

Compare up to 5 products Show