Sistema elettrodinamico certificato di monitoraggio emissioni

STACK 980

Strumento di misurazione polvere certificato da MCERTS come da EN 15859 per un accurato monitoraggio emissioni in basse concentrazioni da processi industriali con filtri a maniche e filtri a cartuccia

Per es. filtri a maniche o a cartuccia.

  • Robust design unaffected by product build-up on the sensor rod
  • No additional services such as air purge required, providing lower cost of ownership
  • Simple maintenance no requirement for specialist service personnel
  • Networking of sensor channels and providing multiple inputs and outputs for external connections
  • Extensively used for measurement (mg/m3) and leak location in bag filter stack applications
  • Advanced sensor design includes drift checks (zero and span) and contamination checks
  • Passive/Active and fully insulated sensor options available for applications with stack condensation and damp particulate prevents potential short circuit to stack wall
  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases
  • Variable velocities within range 8 – 20 m/s (typical bag filter velocity ranges), constant velocity required outside this range
  • After process dryers
    Typical Applications:

  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg Detergent / Carbon Black)
  • Power Generation Plant (eg Coal/Biomass)
Technical Specifications
Measured parameters Dust
Technology ElectroDynamic™ Advanced Probe Electrification
Measurement/Monitoring capability 0-1000 mg/m3*
Stack/Duct diameter suitability up to 8m
Flue gas temperature up to 800°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) /
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
Fully insulted PTFE coated
Passive/Active
QA checks YES

*Application dependant

Technical data
Measurement capability 0 – 1000 mg/m3
Sensor Variants 316 Stainless Steel / Fully insulated PTFE coated (option) / Passive/Active (option)
Stack Temperature Ranges 0 -250°C up to 800°C (option)
Functionality and QA Checks Automatic zero and span / Short circuit check / Contamination check / Drift checks
Data Output RS485 (Modbus) output to Controller
Air Purge option
Enclosure Protection Rating IP66
  • MCERTs certified to EN15859 (Filter Dust monitor)
  • EX Zone 2, 20
  • US EPA MACT Compliant BLD

CASI DI STUDIO CORRELATI