Mesure de la vitesse des solides
Mesure en continu de la vitesse des granulés, poudres et poussières qui sont transportées en chute libre ou en pneumatique dans les procedés industriels
Spécialement conçu pour la mesure continue de la vitesse des solides et des particules telles que les granulés, les poudres et les poussières, qui sont transportés en chute libre ou en transport pneumatique. Utilise la technologie de corrélation triboélectrique.
Capteur à plugger pour un rétrofit facile
- Features & Benefits
- Main applications
- Technical Specifications
- Technical Data
- Mounting Installation
- Downloads
- Continuous speed measurement of solids (powder, granules, dust ) in metal pipes
- Measurement directly in the conveying stream / entrained flow
- Measurement is completely independent of material
- Simple retrofitting using a welding socket
- Energy
Technical Specifications | |
---|---|
Material to measure | Dust, powders or granulates |
Working principle | Correlation |
Process pressure | Max. 1 bar |
Process temperature | Max. +80°C, optional +120°C |
Mounting | Via process connection |
Type of Conveying | Pneumatic leanphase |
Velocity range | 0,75…35 m/s |
Pipe diameter | No limit |
ATEX rating | None |
Output | 4…20mA, Modbus, Profibus |
- Materials: Granules, Powder and dust
- In metal pipes
- Can be used in free fall lines or in pneumatic conveyors
- Range of application: starts with material speed as low as 0.75 m/s
Sensor Technical Data | |
---|---|
Weld-on socket | St52 or steel 1.4571 |
Rod | Wolframcarbid |
Housingn | Steel 1.4571 |
Protection category | IP 65 to EN 60529/10.91 |
Rod length | 15 mm |
Velocity range | 0.75…35 m/s/td> |
Temperature inside the pipe | -20…+80 °C (higher temperature on request) |
Temperatur outside the pipe | 0…+60 °C |
Power supply | 24 V DC |
Weight | Approx. 1.5 kg |
Dimensions | Ø 60, Ø 20, L 320 mm (incl. rod length) |
Measuring accuracy | ± 1 % (in the calibrated measuring range) |
Transmitter Technical Data | ||||
---|---|---|---|---|
Transmitter (DIN Rail) | Transmitter (field housing) | |||
Power supply | 24 V DC ±10 % | 110 / 230 V AC 50 Hz (optional 24 V DC) |
||
Power consumption | 20 W / 24 VA | |||
Protection type | IP 40 to EN 60 529 | IP 65 to EN 60 529/10.91 | ||
Ambient operating temperature | -10 … +45 °C | |||
Dimensions (W x H x D) | 23 x 90 x 118 mm | 258 x 237 x 174 mm | ||
Weight | Approx. 172 g | Approx. 2.5 kg | ||
Connection terminals cable cross-section |
0.2-2.5 mm2 [AWG 24-14] | |||
Current output | 1 x 4 … 20 mA (0 … 20 mA), load < 500 Ω |
3 x 4 … 20 mA (0 … 20 mA), load < 500 Ω |
||
Interface | RS 485 (ModBus RTU) / USB | |||
Pulse output | Open collector – max. 30 V, 20 mA | |||
Relay contact | Max. rated load: 250 V AC Max. peak current: 6 A Max. rated load 230 V AC: 250 VA Max. breaking capacity DC1: 3/110/220 V: 3/0.35/0.2 A Min. switching load: 500 mW (10 V / 5 mA) |
|||
Data backup | Flash memory |
For the assembly of the sensor, the installation location is specified in accordance with the conveyed inlet and outlet paths. The socket is welded on at the specified installation location and then a borehole of 20 mm is drilled through the socket and through the line. The sensor is then adjusted to the wall thickness, inserted and fixed with the help of the coupling nut. The distance between sensor and analysis unit can be a maximum of 300 m. |