Mesure de poussières par technologie Light Scatter

DM 170

Analyseur de poussière conforme aux attentes du TÜV au regard de la norme EN 15267 pour la mesure de particules dans de nombreuses applications industrielles

Système non intrusif sans piège à lumière, adapté aux fumées sans condensation, abrasives/corrosives et chargées en poussières

S’installe d’un seul côté du conduit : facilité d’installation, diminution du risque de contamination des éléments optiques, maintenance aisée.

  • ProScatter™ Backscatter sensor technology with superior minimum detection as low as 1mg/m3 compared to conventional techniques
  • Manual and remote Zero and Span (Reference) checks available to ensure optimal instrument performance
  • Purge Flow Fail Sensor and Optical Shield options
    li>Offers a more reliable PM dust measurement as an alternative to Opacity and Scintillation based monitors for emissions that are reported in mg/m3 and provides
    early indication of increased dust emissions in processes with low dust concentrations
  • Non-intrusive system designed to operate in noncondensing stack environments and to reduce the risk of contamination
  • Contamination risks are further reduced due to singleside stack installation where critical optical components remain outside the stack
  • A Flue Gas Blocker can be fitted to ensure that flue gases do not escape when the unit is opened (for auditing/maintenance purposes), thus enhancing on-site personnel safety
The DM 170 is well-suited for use in medium to large stacks and is suitable for low to high dust concentration measurements, regardless of dust velocity or charge.

    Typical applications include:

  • Continuous Emission Monitoring (CEM) relative to Emission Limit Values (ELV) in Power Plant, Boiler and Metal Smelting applications
  • Filter performance monitoring in Metal, Mineral and Chemical plants
Technical Specifications
Measured parameters Dust
Technology ProScatter™ Backscatter
Measurement/Monitoring capability <1 – 1000 mg/m3
Stack/Duct diameter suitability 1.5 to 15 m (5- 50 ft)
Flue gas temperature -20°C to 250°C (-4°F to 482°F)
option: up to 400°C (752°F)
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
QA checks YES
Technical data
Measurement capability <1 – 1000 mg/m3
Sensor Variants 316 Stainless Steel
Stack Temperature Ranges -20°C – 250°C up to 400°C option
Functionality and QA Checks Automatic zero and span
Data Output RS485 (Modbus) output to Controller
Air Purge option
Enclosure Protection Rating IP65
Designed to comply with the TÜV suitability testing scheme to EN 15267

ÉTUDE DE CAS ASSOCIÉES