Mesure de l’opacité des gaz de combustion

STACK 710

Appareil de mesure des émissions de particules certifié QAL1 et conforme à l’US EPA PS-1 pour le contrôle de la concentration en poussière et de l’opacité dans les gaz de combustion

Réflecteur cubique multi-angles offrant une meilleure réflexion de la lumière transmise par rapport aux réflecteurs traditionnels de type “miroir”, ce qui permet d’obtenir une plus grande confiance dans les mesures

Très robuste, besoin en maintenance extrêmement réduit

  • Outstanding reliability with no continuously moving parts
  • Automatic in-situ zero and span checking with built-in calibration audit and zero drift correction
  • Dual light source, with patented Flood LED source provides robust check of the detectors
    and minimises effects of temperature instability
  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases
    Typical Applications:

  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg Refinery / Rubber)
  • Power Generation Plant (eg Coal/Biomass)
Technical Specifications
Measured parameters Dust
Technology Opacity
Measurement/Monitoring capability 0-100%*
Stack/Duct diameter suitability up to 10m
Flue gas temperature up to 600°C
Baghouse YES
Cartridge Filter /
Ceramic Filter /
Coalescent Filter /
Cyclone /
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Cast aluminium, epoxy coated
QA checks YES
*Application dependant
Technical data
Measurement capability 0 – 100% (opacity); 0-1000 mg/m3 (concentration)
Sensor Variants cast aluminium, epoxy coated
Stack Temperature Ranges up to 600°C
Functionality and QA Checks Automatic zero and span; automatic correction for zero drift
Interface – Available as standalone sensor pair (no controller) or with either standard control unit (Interface module) for single stack or with ProController for multi-sensor networks
– Available with standard control unit (Interface module) for single stack or with ProController for multi-sensor networks
On-board data logging (control unit only) User configurable Long term, Short term or Pulse logging
Output RS232, RS485 (Modbus), Ethernet Digital Alarm and 4/20mA (number of outputs dependant on system configuration (with or without controller)
Air Purge blower required
Enclosure Protection Rating IP65
  • TÜV (UBA) certified to EN15267-3
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181
  • US EPA PS-1 compliant
  • GOST Approved