ANALYSEUR DE O₃ OZONE SÉRIE-E
Utilise une technologie unique de Photométrie UV avec une LED (brevetée) : l’O342e est le premier analyseur d’ozone certifié sur le marché n’utilisant pas de lampe à mercure comme source d’excitation
Analyseur de référence éco-conçu pour la mesure de la qualité de l’air utilisant la technologie de photométrie UV à base de LED (breveté). Certifié QAL1 par le TÜV, homologué US-EPA, LCSQA
- Features & Benefits
- Main applications
- Technical Specification
- Technical Data
- Approvals & Certifications
- Downloads
- Cost-saving ozone monitor with ultra low power consumption, 24 V supply (option) and able to withstand temperatures up to 45-50 °C without air conditioning
- Maximum efficiency, minimum size: compact, lightweight, offering the best metrological performances for O3 measurements in the range of 0-500 ppb or 0-10 ppm
- Real-time calibration graph, animated synoptic, auto-diagnostic, control and maintenance data screens can be displayed while the instrument is operating
- Simultaneous multi-screen remote emulation of the analyzer: minimizes training and on-site expensive expertise needs
- Service assistant inside: detects early signs of trouble, allows predictive maintenance, identifies the service needed and guides the service operations step by step
- User-friendly: one click to perform zero, span or calibrations using O3 gas generators
- Automatic recognition of plugged electronic boards or optional devices: plug and play principle.
- Embedded Communication Protocol for XR® Software with automatic recognition and configuration
- Smart, connected instrument with embedded web server for the easiest, full remote control and operation of the analyzer from any PC, tablet or smartphone (configuration, calibration, test, diagnostic parameters…)
- Ozone monitor for regulatory compliance: continuous indoor and outdoor air quality monitoring
- Mobile AAQMS laboratories and fixed air quality monitoring stations for pollution monitoring
- Compact, Solar powered or on battery air quality monitoring stations ( Green energy )
- Industrial fence-line monitoring
- Continuous emissions monitoring (CEM) by dilution
- Background (urban or suburban), Rural, Traffic, Kerbside measurement campaigns and monitoring studies
- Laboratory and field studies on ozone effects
Technical specifications | |
---|---|
Measured parameter | O₃ |
Technology | UV photometry & LED |
US-EPA Approval / QAL 1 Certification | YES |
Measurement ranges | 0-1 ppm / 0-10 ppm |
Measurement units | ppb, ppm, µg/m3 (user-selectable) |
Lower Detectable Limit (2σ) | 0.2 ppb |
Noise (σ) | 0.1 ppb |
Zero drift | < 0.5 ppb / 24h, < 1 ppb / 7 days |
Span drift | < 0.5% / 24h, < 1% / 7days |
Linearity | ± 1% FS |
Sample flow rate | 1L/min |
Sampling pump | Internal |
Temperature range | 0°C to +35°C |
Data storage | 1 year |
Included I/O | 1LAN/3USB/WIFI/2DRY |
Weight (Kg) | 9.5 |
Dimensions mm (LxWxH) | 483 x 606 x 133 |
Chassis | 19″ Rack, 3U |
Power supply | ‘100~250Vac, 50/60Hz + ground |
Pressure and temperature compensation | YES |
- MAIN OPTIONS:
- TFT color touch screen (800 x 480 , 7″)
- 24 V Power supply PLUS extended temperature range 0-50°C for utilization without air conditioner
- COMPLIANCE WITH:
- 2008/50/EC, EN 14625 (2012), EN 15267 40 CFR PART 53 AND 40 CFR PART 58
- QAL 1 certified by the TÜV to N° 0000043106
- U.S. EPA approved as compliant with EQOA-0515-225