Partikelfilter-staubmessgerät

DM 210

Unter Verwendung der patentierten ElectroDynamicTM Technologie ist der DUST MONITOR 210 ein Filterbruch-Überwachungssystem, das sich für Filterkontrollanwendungen nach Filteranlagen mit Gewebestaubfiltern eignet.

Das Gerät bietet eine robuste und zuverlässige Leckageüberwachung von Filtern an. Optionen für UKEX/ ATEX /IECEx-Explosionszonen und eigenständige oder kontrollierte Einheitssysteme verfügbar.

  • High-quality leak response with sufficient dynamic range and time response to track emissions from single and multi-compartment pulse cleaned bag filters
  • System self-checks (drift checks) to validate measurement integrity including automatic Zero and Span checking
  • Insulated sensor rod option for unmatched performance in applications where water condensation is likely
  • Integrated user interface with keypad and display for intuitive instrument set-up and use
  • 0-100% or user scalable display, of assistance to plant operators wishing to manually scale the display to an approximate known dust level
The DM210 is used to monitor emissions from the following types of processes:

  • Quarrying eg Rotary Dryers, Roller Mills
  • HEPA filters e.g. pharmaceutical/biomedical plant
  • Coal Mill / Cement Mill/ Cement Kiln arrestment plant
  • Humid applications eg Dryers, Calcinators
  • Wood cutting & chipping plant
Technical Specifications
Measured parameters Dust
Technology Electrodynamic™ Probe Electrification
Measurement/Monitoring capability 0-500 mg/m3 (Leak monitoring)
Stack/Duct diameter suitability 0.5 to 8 m
Flue gas temperature 250°C standard, 400°C option
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) NO
Wet Electrostatic Precipitator (WESP) NO
Wet Scrubber NO
Sensor variants 316 stainless, or fully insulted PTFE coated option for conductive dust or humid flue gas application (Sensor Probe)
QA checks YES if required by the user or regulator.
Technical data
Measurement capability 0-500 mg/m3 (Leak monitoring)
Sensor Variants 316 stainless, or fully insulted PTFE coated option for conductive dust or humid flue gas application (Sensor Probe)
Stack Temperature Ranges 250°C up to 400°C option
Functionality and QA Checks Automatic zero and span
Data Output RS485 (Modbus) output to Controller
Air Purge option
Enclosure Protection Rating IP65 die-cast aluminium Enclosure
ATEX
  • UKEX/ ATEX / IECEx Dust Zones 20, 21, 22
  • US EPA MACT Compliant

APPLIKATIONSBEISPIELE