FTIR Multi-Gas Analysator

MIR FT

Gleichzeitige Messung, von bis zu 50 frei wählbaren Parametern, mit einem einzigen und MCERTs zertifizierten Multi-Gas-Analysator

Basierend auf der FTIR-Technologie (Fourier-Transformation-Infrarot) zur gleichzeitigen Messung von : HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CH4, TOC, H2O, CO2, O2

  • 180°C heated sample line / measurement cell (in association with HOFI sampling system according to the application), ensuring no sample loss or composition changes
  • Turnkey system including Industrial PC with Windows based eSAM FT software for on-board data acquisition and processing
  • TOC measurement by FID possible, using the complementary Graphite 52M analyzer
  • Ideal for measuring trace concentrations in wet, corrosive gas streams
  • Suited for hot wet measurements of soluble gases such as HCl, HF, NH3, etc.
  • All in one system including industrial PC & software for on-board data acquisition and processing
  • Municipal, Industrial, Hospital waste incinerators
  • Biomass, Cement Kilns, Pulp & Paper, Glass Plants
  • DeNOx (SNCR, SCR) applications
  • Power & Combustion
Measurable parameters
Pollutant Range
HCI 0-15 / 500
HF 0-3 / 100
NO 0-200 / 2000
NO2 0-200 / 2000
N2O 0-100 / 500
NOx 0-200 / 2000
SO2 0-75 / 20000
CO 0-75 / 10000
CH4 0-15 / 1000
THC 0-50 / 1000
NH3 0-15 / 500
H2O(%) 0-30 / 40
CO2(%) 0-10 / 30
O2(%) 0-10 / 25
Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)
Technical Specifications
QAL1 to EN 15267-3 certified YES
US EPA compliance YES
Sampling technology Hot/Wet Extraction
Sample transfert 180°C heated sampling line
back flush function YES
span injection YES on analyser or at sample point
Built-In O2 option YES
Serial link communication /
Other Communication Ethernet
Analogue OUTPUTS Optional
Analogue INPUTS Optional
Dimensions (mm) 19” rack: 616 x 483 x 220 (DxWxH)
    COMPLIANCE WITH IED 2010 APPLICATIONS

  • QAL 1 certified by the MCERTs to EN 15267-3
    MCERTs QAL 1 certified gas monitor
    Sira MC 040031/11
  • QAL3 compliance as defined by EN 14181
  • U.S. EPA approved as compliant with 40 CFR 60 ET 75
  • Certified by the Korean NIER
The MIR 9000 multi-gas CEMS offer compliance with EU Regulation IED (WID / LCPD / MCP directive) BREF Incineration, US EPA (40 CFR 60 & 75)

  • QAL 1 certified by the TÜV and the MCERTs to EN 15267
0000024158 MCERTs QAL 1 certified gas monitorSira MC020010/13
  • QAL3 compliance as defined by EN 14181
  • U.S. EPA approved as compliant with 40 CFR 60 ET 75

 

 

APPLIKATIONSBEISPIELE