Multi-Gas NDIR-GFC Analysator
Ermöglicht die gleichzeitige und kontinuierliche Messung mit Probenahme auf Trockenbasis von HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 et O2.
Multi-Gas-NDIR-GFC-Analysator (Nicht-dispersive Infrarot-Gasfilterkorrelation), der bis zu zehn Gase gleichzeitig misst, darunter Stickstoffoxid (NO), Stickstoffdioxid (NO2), Schwefeldioxid (SO2), Kohlenmonoxid (CO), sogar Chlorwasserstoff (HCl) und Fluorwasserstoff (HF).
Inzwischen wurden weltweit bereits mehr als 5.000 MIR 9000 Messsysteme zur kontinuierlichen Emissionsmessung und Prozessüberwachung verbaut.
- Features & Benefits
- Main applications
- Technical Specification
- Technical Data
- Approvals & Certifications
- Downloads
- The MIR 9000 is the most popular ENVEA extractive multi-gas analyzer, being used in all type of industries and compliant with all regulations worldwide
- Designed to measure dry & corrosive samples
- Fast & simultaneous measurements of up to 10 gases
- Dry basis measurement
- Automatic cross interference correction
- Ideally used with SEC® box permeation sample drying technology and non-heated sample lines for cost effective operations
- Intrinsic security with residual H2O measurement
- Built-in paramagnetic cell for O2 monitoring
- The MIR-9000 is either available in a 19″ rack or wall mount enclosure (Tight box version)
- Stack emission compliance for Municipal and Hazardous Waste Incinerators
- Cogeneration, Gas Turbines (for ultra-low NOx measurements we recommend the use of the model MIR 9000 CLD)
- Industrial Boilers and Furnaces
- Power & Combustion
- Cement Kilns, Glass, Chemical & Petrochemical Plants
- Efficiency control for DeNOx systems to guarantee their proper performance
- For pre and post catalyst SO2 monitoring (DeSOx unit process control) we recommend the use of the model MIR 9000ASD
Measurable parameters | ||||
---|---|---|---|---|
Pollutant | Range | |||
HCI | 0-15 / 5000 | |||
HF | 0-20 / 300 | |||
NO | 0-100 / 5000 | |||
NO2 | 0-100 / 1000 | |||
N2O | 0-20 / 1000 | |||
NOx | 0-200 / 5000 | |||
SO2 | 0-75 / 5000 | |||
CO | 0-75 / 1000 | |||
CH4 | 0-10 / 1000 | |||
THC | 0-50 / 5000 | |||
CO2(%) | 0-10 / 100 | |||
O2(%) | 0-10 / 25 |
Other ranges available upon request
Technical Specifications | |
---|---|
QAL1 to EN 15267-3 certified | YES |
US EPA compliance | YES |
Sampling technology | Cold/Dry Extraction |
Sample transfert | non heated polytube |
back flush function | YES |
span injection | YES on analyser or at sample point |
Built-In O2 option | YES |
Serial link communication | RS232 / RS422 |
Other Communication | Ethernet |
Analogue OUTPUTS | Optional |
Analogue INPUTS | Optional |
Dimensions (mm) | • Tight box version: 200 x 400 x 600 (D x W x H) • 19” rack version: 490 x 483 x 177 (D x W x H) |
- MCERTS & TÜV QAL 1 certified MIR-9000 multi-gas emissions analyzer
- Graphite 52M FID (If working to EN12619 VOC standard)
- Sample extraction and conditioning probe (with or without integrated temperature, pressure and flow measurement)
- SEC® sampling system (permeation based) or gas cooler
- Sample lines
- Automatic calibration units (TIG)
- Instrument air drying system (MDS)
- Multiplexing system (MVS) for dual redundancy*
- Rack cabinet, cubicle or shelter integration
- MCERTs Certified ENVEA WEX Data acquisition & management system
*Dual Redundancy System
Under the IED, the maximum period allowed for any one episode of abatement or equipment failure must not exceed four hours. Additionally, the total allowance period for a year must not exceed sixty hours.
The ENVEA duplex philosophy has therefore been specifically developed to assist you in complying with IED by reducing downtime, maximising availability and ensuring you achieve a sound return on your investment.
- QAL 1 certified by the TÜV and the MCERTs to EN 15267
- QAL3 compliance as defined by EN 14181
- U.S. EPA approved as compliant with 40 CFR 60 ET 75